Nima Asadi; Hamid Soleimanimehr; Aida Mohammad Sadegh
Abstract
Due to the quality of the water entering the water purifiers, sometimes the amount of solutes and hardness in the water is so high that after a short time, these systems become clogged or full. To solve this problem. Several methods have been proposed in this study, acid injection and its effect on reverse ...
Read More
Due to the quality of the water entering the water purifiers, sometimes the amount of solutes and hardness in the water is so high that after a short time, these systems become clogged or full. To solve this problem. Several methods have been proposed in this study, acid injection and its effect on reverse osmosis system by wave software have been investigated. To ensure the condition and accuracy of the incoming water, the necessary tests were performed through the laboratory and the condition of the water and the number of ions and its salts were reported. By injecting acid into the inlet water, the pH value was reduced from 7.58, which is the normal pH of the water, to 5 by micrograph in 0.2 intervals, and after examination, the following results were obtained: With decreasing pH, the LSI number has a suitable decrease, so that at pH 6.1 and lower, the LSI number is negative and this indicates the lack of premature fouling. However, with this reduction, the acidic property of the treated water increases and the possibility of chemical corrosion of the industrial equipment used increases, on the other hand, by injecting acid and lowering the pH, the amount of TDS increased, which should be tried in different ways to minimize this amount. In comparison between injections of two acids performed under the same conditions, the amount of TDS at the time of H2SO4 injection at the pH limit was 10% less than the time of HCl injection.
Nafiseh Aghababaei
Abstract
Reverse osmosis (RO) has proven to be an efficient technique for desalination of seawater, brackish water, and reclaimed wastewater. However, the performance of RO desalination is sensitive to its design parameters and operating conditions. The purpose of this study was to modeling the removal of total ...
Read More
Reverse osmosis (RO) has proven to be an efficient technique for desalination of seawater, brackish water, and reclaimed wastewater. However, the performance of RO desalination is sensitive to its design parameters and operating conditions. The purpose of this study was to modeling the removal of total dissolved solids (TDS) and Rejection of different ions are reported from water of city of Bandar Abbas. The main purpose of this work was the prepared drinking water intrusion model. In this study, a design method based on a simulation technique has been developed for optimizing RO desalination systems. The design is made with the use of Hydranautics design software version 2011. In this paper main focus is on the design part with software. The desalinated water obtained from reverse osmosis at a pressure of 1.2 MPa showed rejections of approximately 88.49 % for SO4 2 −, 61.42 % for TDS, 70.34 for Cl- and 50.85 for Na+. It shows that software gives accurate design with least possible error and user friendly so world while accepted. Blended water, produced by mixing groundwater and surface, was proposed to optimize the produce drinking water with a recovery rate of 95 %. Reverse osmosis is an excellent alternative for the supply of water in Bandar Abbas.